| Foto | Hersteller-Teilenr. | Verfügbarkeit | Menge | Datenblatt | Serie | Verpackung | Produktstatus | Verwendeter Bereich | Form | Eingabetyp | Spannungseingang | Spannung – Ausgang | Strom – Ausgang (Max) | Leistung (Watt) | Leerlaufleistung Verbrauch | Polarisation | Anwendungen | Effizienz | Betriebstemperatur | Ausgangsanschluss | Kabellänge | Eingangsanschluss | Funktionen | Größe/Abmessung | Zulassungsstelle | Standardnummer | 
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|  | SDI24-48-UD2-P6AC/DC DESKTOP ADAPTER 48V 24W | 4,672 |  |   Datenblatt | SDI24-UD (24W) | Box | Active | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 48V | 500mA | 24 W | 75mW (Max) | Positive Center | ITE (Commercial) | Level VI, CoC Tier 2 | 0°C ~ 40°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | - | 3.48" L x 1.97" W x 1.34" H (88.5mm x 50.0mm x 34.0mm) | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | 
|  | SDI24-48-UD2-P6RAC/DC DESKTOP ADAPTER 48V 24W | 3,537 |  |   Datenblatt | SDI24-UD (24W) | Box | Active | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 48V | 500mA | 24 W | 75mW (Max) | Positive Center | ITE (Commercial) | Level VI, CoC Tier 2 | 0°C ~ 40°C | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | - | 3.48" L x 1.97" W x 1.34" H (88.5mm x 50.0mm x 34.0mm) | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, RCM, UL | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | 
|   | SMM12-6-4W-CUBAC-DC, 6 VDC, 2 A, SW, MULTI-BLA | 2,671 |  |   Datenblatt | - | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 
|   | SMI36-24-B-STAC/DC WALL MOUNT ADAPTER 24V 36W | 1,745 |  |   Datenblatt | SMI36 (36W) | Box | Active | United Kingdom | Wall Mount (Class II) | Multi-Blade (Included) | 90 ~ 264 VAC | 24V | 1.5A | 36 W | 100mW (Max) | - | ITE (Commercial) | Level VI, CoC Tier 2 | 0°C ~ 40°C | Stripped, Tinned Wire Leads | 59" (1.50m) | Multi-Blade (Included) | - | 3.09" L x 1.39" W x 2.60" H (78.5mm x 35.3mm x 66.0mm) | CB Scheme, CCC, CSA, EN, FCC, IEC, PSE, UL | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 62368-1 | 
|   | GEM12I15-P1JAC/DC WALL MOUNT ADAPTER 15V 12W | 1,076 |  |   Datenblatt | GEM12I (12W) | Box | Obsolete | International | Wall Mount (Class II) | Multi-Blade (Sold Separately) | 80 ~ 264 VAC | 15V | 800mA | 12 W | 75mW (Max) | Positive Center | Medical | Level VI | -20°C ~ 70°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 11.0mm | 70.9" (1.80m) | Multi-Blade (Sold Separately) | - | 2.91" L x 1.54" W x 1.91" H (73.9mm x 39.0mm x 48.5mm) | CE, cURus, TUV | - | 
|   | SWI36-16-N-P10AC-DC, 16 VDC, 2.25 A, SW, WALL- | 3,710 |  |   Datenblatt | SWI36-N (36W) | Box | Active | North America | Wall Mount (Class II) | Fixed Blade | 90 ~ 264 VAC | 16V | 2.25A | 36 W | 100mW | Positive Center | ITE (Commercial) | Level VI, CoC Tier 2 | -20°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | NEMA 1-15P | - | 3.11" L x 1.34" W x 2.20" H (79.0mm x 34.0mm x 56.0mm) | cULus, PSE | 62368-1 | 
|   | SWI36-15-N-P10AC-DC, 15 VDC, 2.40 A, SW, WALL- | 4,317 |  |   Datenblatt | SWI36-N (36W) | Box | Active | North America | Wall Mount (Class II) | Fixed Blade | 90 ~ 264 VAC | 15V | 2.4A | 36 W | 100mW | Positive Center | ITE (Commercial) | Level VI, CoC Tier 2 | -20°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | NEMA 1-15P | - | 3.11" L x 1.34" W x 2.20" H (79.0mm x 34.0mm x 56.0mm) | cULus, PSE | 62368-1 | 
|   | SWI36-13.5-N-P11AC-DC, 13.5 VDC, 2.66 A, SW, WAL | 1,457 |  |   Datenblatt | SWI36-N (36W) | Box | Active | North America | Wall Mount (Class II) | Fixed Blade | 90 ~ 264 VAC | 13.5V | 2.66A | 36 W | 100mW | Positive Center | ITE (Commercial) | Level VI, CoC Tier 2 | -20°C ~ 40°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | NEMA 1-15P | - | 3.11" L x 1.34" W x 2.20" H (79.0mm x 34.0mm x 56.0mm) | cULus, PSE | 62368-1 | 
|   | SWI36-15-N-P11AC-DC, 15 VDC, 2.40 A, SW, WALL- | 1,334 |  |   Datenblatt | SWI36-N (36W) | Box | Active | North America | Wall Mount (Class II) | Fixed Blade | 90 ~ 264 VAC | 15V | 2.4A | 36 W | 100mW | Positive Center | ITE (Commercial) | Level VI, CoC Tier 2 | -20°C ~ 40°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | NEMA 1-15P | - | 3.11" L x 1.34" W x 2.20" H (79.0mm x 34.0mm x 56.0mm) | cULus, PSE | 62368-1 | 
|   | SWI36-12-N-P10AC-DC, 12 VDC, 3 A, SW, WALL-PLU | 1,297 |  |   Datenblatt | SWI36-N (36W) | Box | Active | North America | Wall Mount (Class II) | Fixed Blade | 90 ~ 264 VAC | 12V | 3A | 36 W | 100mW | Positive Center | ITE (Commercial) | Level VI, CoC Tier 2 | -20°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | NEMA 1-15P | - | 3.11" L x 1.34" W x 2.20" H (79.0mm x 34.0mm x 56.0mm) | cULus, PSE | 62368-1 | 
|   | SWI36-18-N-P10AC-DC, 18 VDC, 2 A, SW, WALL-PLU | 1,486 |  |   Datenblatt | SWI36-N (36W) | Box | Active | North America | Wall Mount (Class II) | Fixed Blade | 90 ~ 264 VAC | 18V | 2A | 36 W | 100mW | Positive Center | ITE (Commercial) | Level VI, CoC Tier 2 | -20°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | NEMA 1-15P | - | 3.11" L x 1.34" W x 2.20" H (79.0mm x 34.0mm x 56.0mm) | cULus, PSE | 62368-1 | 
|   | SWI36-16-N-P11AC-DC, 16 VDC, 2.25 A, SW, WALL- | 2,538 |  |   Datenblatt | SWI36-N (36W) | Box | Active | North America | Wall Mount (Class II) | Fixed Blade | 90 ~ 264 VAC | 16V | 2.25A | 36 W | 100mW | Positive Center | ITE (Commercial) | Level VI, CoC Tier 2 | -20°C ~ 40°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | NEMA 1-15P | - | 3.11" L x 1.34" W x 2.20" H (79.0mm x 34.0mm x 56.0mm) | cULus, PSE | 62368-1 | 
|   | SWI36-24-N-P10AC-DC, 24 VDC, 1.5 A, SW, WALL-P | 3,231 |  |   Datenblatt | SWI36-N (36W) | Box | Active | North America | Wall Mount (Class II) | Fixed Blade | 90 ~ 264 VAC | 24V | 1.5A | 36 W | 100mW | Positive Center | ITE (Commercial) | Level VI, CoC Tier 2 | -20°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | NEMA 1-15P | - | 3.11" L x 1.34" W x 2.20" H (79.0mm x 34.0mm x 56.0mm) | cULus, PSE | 62368-1 | 
|   | SWI36-18-N-P11AC-DC, 18 VDC, 2 A, SW, WALL-PLU | 3,545 |  |   Datenblatt | SWI36-N (36W) | Box | Active | North America | Wall Mount (Class II) | Fixed Blade | 90 ~ 264 VAC | 18V | 2A | 36 W | 100mW | Positive Center | ITE (Commercial) | Level VI, CoC Tier 2 | -20°C ~ 40°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | NEMA 1-15P | - | 3.11" L x 1.34" W x 2.20" H (79.0mm x 34.0mm x 56.0mm) | cULus, PSE | 62368-1 | 
|   | SWI36-13.5-N-P10AC-DC, 13.5 VDC, 2.66 A, SW, WAL | 3,030 |  |   Datenblatt | SWI36-N (36W) | Box | Active | North America | Wall Mount (Class II) | Fixed Blade | 90 ~ 264 VAC | 13.5V | 2.66A | 36 W | 100mW | Positive Center | ITE (Commercial) | Level VI, CoC Tier 2 | -20°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | NEMA 1-15P | - | 3.11" L x 1.34" W x 2.20" H (79.0mm x 34.0mm x 56.0mm) | cULus, PSE | 62368-1 | 
|   | SWI36-12-N-P11AC-DC, 12 VDC, 3 A, SW, WALL-PLU | 3,517 |  |   Datenblatt | SWI36-N (36W) | Box | Active | North America | Wall Mount (Class II) | Fixed Blade | 90 ~ 264 VAC | 12V | 3A | 36 W | 100mW | Positive Center | ITE (Commercial) | Level VI, CoC Tier 2 | -20°C ~ 40°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | NEMA 1-15P | - | 3.11" L x 1.34" W x 2.20" H (79.0mm x 34.0mm x 56.0mm) | cULus, PSE | 62368-1 | 
|   | SWI36-24-N-P11AC-DC, 24 VDC, 1.5 A, SW, WALL-P | 3,494 |  |   Datenblatt | SWI36-N (36W) | Box | Active | North America | Wall Mount (Class II) | Fixed Blade | 90 ~ 264 VAC | 24V | 1.5A | 36 W | 100mW | Positive Center | ITE (Commercial) | Level VI, CoC Tier 2 | -20°C ~ 40°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | NEMA 1-15P | - | 3.11" L x 1.34" W x 2.20" H (79.0mm x 34.0mm x 56.0mm) | cULus, PSE | 62368-1 | 
| .jpg)  | TR9KZ3158CCP-N(R6B)AC/DC DESKTOP ADAPTER 19V 60W | 4,258 |  |   Datenblatt | GT-46600-WWVV-X.X-T2 | Bulk | Active | International | Desktop (Class II) | Cord (Sold Separately) | 90 ~ 264 VAC | 19V | 3.15A | 60 W | 150mW (Max) | Positive Center | Household Appliances, ITE (Commercial) | Level VI | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 11.0mm | 60.2" (1.53m) | IEC 320-C8 | - | 4.76" L x 2.05" W x 1.30" H (121.0mm x 52.0mm x 33.0mm) | CB, CCC, CE, cULus, EAC, FCC, GS, LPS, RCM, PSE, UKRSepro, VCCI | 60335-1; 60950-1 | 
|  | SDI30-15-U-P6AC/DC DESKTOP ADAPTER 15V 30W | 1,920 |  |   Datenblatt | SDI30-U (30W) | Box | Obsolete | International | Desktop (Class I) | Cord (Sold Separately) | 90 ~ 264 VAC | 15V | 2A | 30 W | 75mW (Max) | Positive Center | ITE (Commercial) | Level VI | 0°C ~ 40°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 60.2" (1.53m) | IEC 320-C14 | - | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | CB Scheme, CCC, CSA, EN, FCC, IEC, RCM, SIQ, TUV, UL | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 61204-3 | 
|  | SDI30-15-U-P6RAC/DC DESKTOP ADAPTER 15V 30W | 2,119 |  |   Datenblatt | SDI30-U (30W) | Box | Obsolete | International | Desktop (Class I) | Cord (Sold Separately) | 90 ~ 264 VAC | 15V | 2A | 30 W | 75mW (Max) | Positive Center | ITE (Commercial) | Level VI | 0°C ~ 40°C | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 60.2" (1.53m) | IEC 320-C14 | - | 4.37" L x 2.05" W x 1.27" H (111.0mm x 52.0mm x 32.3mm) | CB Scheme, CCC, CSA, EN, FCC, IEC, RCM, SIQ, TUV, UL | C22.2 No. 60950-1; 55024; 55032 Class B; 60950-1; 61000-3-2; 61000-3-3; 61204-3 |